DURING SCHEDULED SPV CHECK, FOUND DOORWAY FRAME DOUBLER CRACKED AT BS 794.5, BETWEEN STR 22R TO STR 26R. REMOVED AND REPLACED DOUBLER PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SPV CHECK, FOUND DOORWAY FRAME DOUBLER CRACKED AT BS 794.5, BETWEEN STR 22R TO STR 26R. REMOVED AND REPLACED DOUBLER PER SRM.