What was found
DURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED BETWEEN BS 669 TO BS 701, BL 0.07. REPAIRED BEAM PER SWA EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED BETWEEN BS 669 TO BS 701, BL 0.07. REPAIRED BEAM PER SWA EA.