What was found
DURING SCHEDULED SPV CHECK, FOUND SHEAR TIE CORRODED AT BS 927, BETWEEN STR 23L TO STR 24L. REMOVED AND REPLACED SHEAR TIE PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SPV CHECK, FOUND SHEAR TIE CORRODED AT BS 927, BETWEEN STR 23L TO STR 24L. REMOVED AND REPLACED SHEAR TIE PER SRM.