What was found
DURING SCHEDULED 22Y CHECK, FOUND L1 DOOR STRINGER SPLICE CHANNEL CRACKED AT BS 360, STR 15L. REMOVED AND REPLACED SPLICE PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 22Y CHECK, FOUND L1 DOOR STRINGER SPLICE CHANNEL CRACKED AT BS 360, STR 15L. REMOVED AND REPLACED SPLICE PER SRM.