What was found
DURING SCHEDULED OTS CHECK, FOUND STRINGER CORRODED BETWEEN BS 1006 TO BS 1016, STR 26L. REMOVED AND REPLACED STRINGER PER SRM AND BAC DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED OTS CHECK, FOUND STRINGER CORRODED BETWEEN BS 1006 TO BS 1016, STR 26L. REMOVED AND REPLACED STRINGER PER SRM AND BAC DWG.