What was found
DURING SCHEDULED 22Y CHECK, FOUND R2 DOOR CUTOUT, AFT VERTICAL RIB CORRODED AT FS 983.5. REPAIRED FRAME PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 22Y CHECK, FOUND R2 DOOR CUTOUT, AFT VERTICAL RIB CORRODED AT FS 983.5. REPAIRED FRAME PER SRM.