What was found
DURING SCHEDULED 16Y CHECK, FOUND STRINGER SPLICE CORRODED AT BS 847, STR 21R. REMOVED AND REPLACED CLIP PER SRM AND BAC DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND STRINGER SPLICE CORRODED AT BS 847, STR 21R. REMOVED AND REPLACED CLIP PER SRM AND BAC DWG.