What was found
DURING SCHEDULED SPV CHECK, FOUND SHEAR TIE CORRODED AT BS 807, BETWEEN STR 27L TO STR 27R. REPAIRED SHEAR TIE PER SRM AND BAC DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SPV CHECK, FOUND SHEAR TIE CORRODED AT BS 807, BETWEEN STR 27L TO STR 27R. REPAIRED SHEAR TIE PER SRM AND BAC DWG.