What was found
DURING SCHEDULED 14Y CHECK, FOUND FLOORBEAM ENTIRE UPPER FLANGE CORRODED AT BS 986. REPAIRED BEAM PER EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 14Y CHECK, FOUND FLOORBEAM ENTIRE UPPER FLANGE CORRODED AT BS 986. REPAIRED BEAM PER EA.