What was found
DURING SCHEDULED 22Y CHECK, FOUND FLOORBEAM T-CAP CORRODED AT BS 986, BETWEEN LBL 4 TO LBL 44. REMOVED AND REPLACED T-CAP PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 22Y CHECK, FOUND FLOORBEAM T-CAP CORRODED AT BS 986, BETWEEN LBL 4 TO LBL 44. REMOVED AND REPLACED T-CAP PER SRM.