What was found
DURING SCHEDULED 18Y CHECK, FOUND FWD GALLEY DOORWAY CREASE BEAM CORRODED. REMOVED AND REPLACED BEAM PER BAC DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 18Y CHECK, FOUND FWD GALLEY DOORWAY CREASE BEAM CORRODED. REMOVED AND REPLACED BEAM PER BAC DWG.