What was found
DURING SCHEDULED 18Y CHECK, FOUND CREASE BEAM CORRODED BETWEEN BS 882 TO BS 887, WL 208. REMOVED AND REPLACED BEAM PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 18Y CHECK, FOUND CREASE BEAM CORRODED BETWEEN BS 882 TO BS 887, WL 208. REMOVED AND REPLACED BEAM PER SRM.