What was found
DURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT MOUTING BRACKET CRACKED. REMOVED AND REPLACED BRACKET IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT MOUTING BRACKET CRACKED. REMOVED AND REPLACED BRACKET IAW SRM AND DWG.