What was found
DURING SCHEDULED 16Y CHECK, FOUND FRAME CORRODED AT BS 787, BETWEEN STR 27L TO STR 27R. REMOVED AND REPLACED FRAME IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND FRAME CORRODED AT BS 787, BETWEEN STR 27L TO STR 27R. REMOVED AND REPLACED FRAME IAW SRM AND DWG.