What was found
DURING SCHEDULED 26Y CHECK, FOUND FLOOR STRUCTURE FLOORBEAM CORRODED AT BS 986.5, RBL 43. REPAIRED BEAM IAW EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 26Y CHECK, FOUND FLOOR STRUCTURE FLOORBEAM CORRODED AT BS 986.5, RBL 43. REPAIRED BEAM IAW EA.