What was found
DURING SCHEDULED RON CHECK, FOUND CREASE BEAM WEB HEAT DAMAGED BETWEEN BS 259 TO BS 277, STR 17R. REMOVED AND REPLACED WEB IAW EA AND EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED RON CHECK, FOUND CREASE BEAM WEB HEAT DAMAGED BETWEEN BS 259 TO BS 277, STR 17R. REMOVED AND REPLACED WEB IAW EA AND EA.