What was found
DURING SCHEDULED SPV CHECK, FOUND CREASE BEAM SHEAR WEB CORRODED BETWEEN BS 380 TO BS 400, STR 17R. REMOVED AND REPLACED WEB PER SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SPV CHECK, FOUND CREASE BEAM SHEAR WEB CORRODED BETWEEN BS 380 TO BS 400, STR 17R. REMOVED AND REPLACED WEB PER SRM AND DWG.