What was found
DURING SCHEDULED 16Y CHECK, FOUND STUB FRAME BEAM ATTACHMENT CLIP CRACKED AT BS 639, RBL 45.5. REMOVED AND REPLACED CLIP IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND STUB FRAME BEAM ATTACHMENT CLIP CRACKED AT BS 639, RBL 45.5. REMOVED AND REPLACED CLIP IAW SRM.