What was found
DURING SCHEDULED 16Y CHECK, FOUND FRAME CORRODED AT BS 1006, BETWEEN STR 20R TO STR 22R. REPAIRED FRAME IAW EO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND FRAME CORRODED AT BS 1006, BETWEEN STR 20R TO STR 22R. REPAIRED FRAME IAW EO.