What was found
DURING SCHEDULED 8Y CHECK, FOUND R1 DOOR CREASE BEAM VERTICAL STRAP CORRODED AT BS 298. REMOVED AND REPLACED BEAM IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 8Y CHECK, FOUND R1 DOOR CREASE BEAM VERTICAL STRAP CORRODED AT BS 298. REMOVED AND REPLACED BEAM IAW SRM AND DWG.