What was found
DURING SCHEDULED 8Y CHECK, FOUND R1 DOOR CREASE BEAM ATTACH ANGLE UPPER SURFACE CORRODED BETWEEN BS 298 TO BS 325. REMOVED AND REPLACED ANGLE IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 8Y CHECK, FOUND R1 DOOR CREASE BEAM ATTACH ANGLE UPPER SURFACE CORRODED BETWEEN BS 298 TO BS 325. REMOVED AND REPLACED ANGLE IAW SRM AND DWG.