DURING SCHEDULED 16Y CHECK, FOUND R2 DOOR CREASE BEAM WEB CRACKED AT BS 1004, BETWEEN RBL 45 TO RBL 50. R&R WEB IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND R2 DOOR CREASE BEAM WEB CRACKED AT BS 1004, BETWEEN RBL 45 TO RBL 50. R&R WEB IAW SRM AND DWG.