What was found
ZEE ANGLE CORRODED AT L1 DOOR LOWER SILL STRUCTURE BETWEEN BS 312 AND BS 344, LBL 63. REMOVED AND REPLACED ZEE ANGLE IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ZEE ANGLE CORRODED AT L1 DOOR LOWER SILL STRUCTURE BETWEEN BS 312 AND BS 344, LBL 63. REMOVED AND REPLACED ZEE ANGLE IAW SRM AND DWG.