What was found
DURING CRUISE, RED & GREEN NOSE GEAR LIGHTS ILLUMINATED WITH THE NOSE GEAR IN THE UP POSITION. ACCOMPLISHED QRH PROCEDURE AND WHEN GEAR LEVER WAS PLACED IN THE DOWN POSITION, ALL GEAR INDICATED DOWN & LOCKED WITH ALL RED LIGHTS EXTINGUISHED. FOUND SENSOR BAD. REMOVED AND REPLACED SENSOR PER MM.