What was found
CRACK INDICATIONS AROUND FORWARD CARGO DOOR OPENING FORWARD AND AFT FRAMES TO SKIN ATTACH FASTENERS, REMOVE FASTENERS FOR NDT CRACK VERIFICATION, ALL FASTENERS MARKED IN BLACK. REMOVED TOTAL OF 11EA. FASTENERS AT FWD CARGO DOOR CUTOUT FRAMES IAW SRM. 8EA FASTENERS REMOVED AT FWD FRAME & 3EA AT AFT FRAME. ACCOMPLISHED HFEC OF FASTENER HOLES WIT 6EA HOLES HAVING NO DEFECT AND 5EA HOLES WITH CRACK INDICATIONS WROTE UP ON SEPARATE NON ROUTINE FOR REPAIR WORK. INSTALLED 8EA FASTENERS AT FRAME BS400, S-22R IAW IAW SRM.