What was found
STRINGER CLIP AT STA 927 S6R IS BROKEN. LOCATED AND DRILLED AS REQUIRED IAW BAC DWG 65-46559 AND B737 SRM 51-40-02. INSTALLED STRINGER CLIP IAW BAC DWG 65-46559 AND B737 SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER CLIP AT STA 927 S6R IS BROKEN. LOCATED AND DRILLED AS REQUIRED IAW BAC DWG 65-46559 AND B737 SRM 51-40-02. INSTALLED STRINGER CLIP IAW BAC DWG 65-46559 AND B737 SRM 51-40-02.