What was found
CRACK ON STRINGER SPLICE LOCATED AT BSTA 360 STR 2L FWD CABIN. REPLACED RIVETS 2EA ON STRINGER SPLICE LOCATED AT BS 360 STR 2L FWD CABIN IAW SRM B737-500 51-40-02 AND DWG 65-45765.