What was found
AD DRIVEN: AFT PIT STA 794, RBL 8, LONGITUDINAL FLOOR SUPPORT LOWER SURFACE, 1EA FASTENER HOLE, EXFOLIATED. REPAIRED LONGITUDINAL FLOOR SUPPORT AT STA 794 RBL 8 IAW SRM 53-00-53-2R-1 & EA 1-A53-2021 REV 7 WITH A NESTED ANGLE REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AD DRIVEN: AFT PIT STA 794, RBL 8, LONGITUDINAL FLOOR SUPPORT LOWER SURFACE, 1EA FASTENER HOLE, EXFOLIATED. REPAIRED LONGITUDINAL FLOOR SUPPORT AT STA 794 RBL 8 IAW SRM 53-00-53-2R-1 & EA 1-A53-2021 REV 7 WITH A NESTED ANGLE REPAIR.