What was found
FWD ENTRY FLOOR STRUCTURE HAS A INTERCOSTAL CRACKED AT LBL 45 AND BETWEEN STA 328 AND 312. REMOVED AND REPLACED INTERCOSTAL IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD ENTRY FLOOR STRUCTURE HAS A INTERCOSTAL CRACKED AT LBL 45 AND BETWEEN STA 328 AND 312. REMOVED AND REPLACED INTERCOSTAL IAW SRM.