What was found
FWD PIT STA 500A LBL 19, FWD SIDE, INTERCOSTAL ATTACH BRACKET IS CRACKED. REMOVED CRACKED ANGLE, DRILLED UP AND INSTALLED NEW ANGLE AT STA 500A LBL 19 FWD SIDE IAW SRM 51-40-02 AND DRAWING 143A7505. APPLIED CIC IAW SRM 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT STA 500A LBL 19, FWD SIDE, INTERCOSTAL ATTACH BRACKET IS CRACKED. REMOVED CRACKED ANGLE, DRILLED UP AND INSTALLED NEW ANGLE AT STA 500A LBL 19 FWD SIDE IAW SRM 51-40-02 AND DRAWING 143A7505. APPLIED CIC IAW SRM 51-20-01.