What was found
CRACK ON SHEAR TIE AT THE FWD ENTRY DOOR SURROUND STRUCTURE BS 303.9+6 INCH, STRINGER 15L. REPLACED SHEAR TIE IAW SRM 51-10-02 PAGE 8 AND 51-40-02 DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON SHEAR TIE AT THE FWD ENTRY DOOR SURROUND STRUCTURE BS 303.9+6 INCH, STRINGER 15L. REPLACED SHEAR TIE IAW SRM 51-10-02 PAGE 8 AND 51-40-02 DWG.