What was found
CRACK AROUND HOLE LOCATED ON STRINGER SPLICE AT LEVEL OF STR 2L BS 887+15". REPLACED STRINGER SPLICE AND FASTENERS LOC AT LEVEL STR 2L, BS 907 IAW B737-300 SRM 51-10-02 ITEM 8 AND SRM 51-40-02 AND DRAWING 65-45772.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK AROUND HOLE LOCATED ON STRINGER SPLICE AT LEVEL OF STR 2L BS 887+15". REPLACED STRINGER SPLICE AND FASTENERS LOC AT LEVEL STR 2L, BS 907 IAW B737-300 SRM 51-10-02 ITEM 8 AND SRM 51-40-02 AND DRAWING 65-45772.