What was found
AFT PIT - FLOOR SUPPORT BRACKET CRACKED - AT STA 817 LONG 30 AFT SECTION. REMOVED AND REPLACED INTERCOSTAL AT STA 817 BULKHEAD ABOVE LONGERON 30 IAW B717 SRM 51-41-05, 51-40-08, 51-20-05
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT - FLOOR SUPPORT BRACKET CRACKED - AT STA 817 LONG 30 AFT SECTION. REMOVED AND REPLACED INTERCOSTAL AT STA 817 BULKHEAD ABOVE LONGERON 30 IAW B717 SRM 51-41-05, 51-40-08, 51-20-05