What was found
SSID 11813-53 FIG F-38B, STRINGER SPLICE CRACK IN LOWER HORIZONTAL FLANGE BS 540 STR 10R CRACK LENGTH .75" LONG. BS 540 STR 10R STRINGER SPLICE WAS REMOVED AND REPLACED IAW ATS ER 13-01171 DATED 29JAN13 AND EA 1-353-21583.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SSID 11813-53 FIG F-38B, STRINGER SPLICE CRACK IN LOWER HORIZONTAL FLANGE BS 540 STR 10R CRACK LENGTH .75" LONG. BS 540 STR 10R STRINGER SPLICE WAS REMOVED AND REPLACED IAW ATS ER 13-01171 DATED 29JAN13 AND EA 1-353-21583.