What was found
AFT PIT BILGE, LONGERON 28R HAS AREAS OF CORROSION FS 958 TO FS 927. REMOVED CORROSION AT STA 908 INTERCOSTAL IAW B717 SRM 51-10-04. ORIG MAT .063 REMAINING .039 LOSS OF .024 FOUND TO BE OUT OF LIMITS IAW B717 SRM 53-00-00 FIG 103. FABRICATED NEW INTERCOSTAL IAW B717 SRM 51-40-08 & SMALL CONTROL PO 2040744 FROM 7075 .063 P/O 9957704. HEAT TREATED TI 7075T6 IAW FASER # 2-37153-801 REV A. ALODINED, PRIMED, TOP COATED IAW B717 SRM 51-10-04. INSTALLED INTERCOSTAL IAW B717 SRM 51-41-02 & 51-41-05 & FAY SEALED PARTS IAW B717 SRM 51-20-05, DIM OF INTERCOSTAL (5"X19")