What was found
A 3 INCH, VERTICAL, SUB-SURFACE CHEM-MILL CRACK FOUND DURING NDT INSPECTION, AFT SIDE OF BS 908 SPLICE 5 I INCHES BELOW STR-5L TO 3 INCHES ABOVE STR-6L. CHEM-MILL CRACK AT BS 908 SPLICE 5" BELOW STR 5L TO 3" ABOVE STR 6L WAS REPAIRED IAW ATS ER 13-0277 DATED 12FEB13 AND EA 1-353-21723.