What was found
MID CABIN FLOOR STRUCTURE AT EXPANSION JOINT FLOOR SUPPORT CHANNEL CRACKED AT STATION 540, LBL 1. R & R JOINT IAW SRM & DRAWING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MID CABIN FLOOR STRUCTURE AT EXPANSION JOINT FLOOR SUPPORT CHANNEL CRACKED AT STATION 540, LBL 1. R & R JOINT IAW SRM & DRAWING.