What was found
FWD CABIN FLOOR STRUCTURE LOWER SURFACE OF CHORD BEAM CORRODED AT BS 312, BETWEEN RBL 12 & RBL 50. REPAIRED BEAM IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN FLOOR STRUCTURE LOWER SURFACE OF CHORD BEAM CORRODED AT BS 312, BETWEEN RBL 12 & RBL 50. REPAIRED BEAM IAW SRM.