What was found
SHEAR WEB BELOW AFT LAVATORY CUT OUT IN SHEAR WEB FOR DUMP TUBE CORRODED AROUND CUT OUT. R & R SHEAR WEB IAW SRM & DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR WEB BELOW AFT LAVATORY CUT OUT IN SHEAR WEB FOR DUMP TUBE CORRODED AROUND CUT OUT. R & R SHEAR WEB IAW SRM & DWG.