What was found
DIVERSION, CLIMBING THROUGH FL330 TO FL360, NR 1 BUS OFF LIGHT ILLUMINATED. APU STARTED BELOW FL350 & PLACED ONLINE NR 1 SIDE. HOWEVER, POWER WOULD NOT STAY ONLINE WITH EITHER ENG GEN OR APU SELECTED. ON ITS OWN IT CYCLES ON & OFF;. R & R POWER TRANSFER SIGNAL RELAY R349 IAW MM.