What was found
AFT CARGO COMPARTMENT ATTACH FLOOR TO SIDEWALL SUPPORT ANGLE CRACKED AT BS 947.5, STRINGER 25L. R & R ANGLE IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPARTMENT ATTACH FLOOR TO SIDEWALL SUPPORT ANGLE CRACKED AT BS 947.5, STRINGER 25L. R & R ANGLE IAW SRM.