What was found
AFT CABIN WET AREA FLOORBOARD 242UF, BOTTOM SIDE AFT NUTPLATE FOR DOOR GIRT BAR FITTING MISSING. R & R GIRT BAR ASSEMBLY IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN WET AREA FLOORBOARD 242UF, BOTTOM SIDE AFT NUTPLATE FOR DOOR GIRT BAR FITTING MISSING. R & R GIRT BAR ASSEMBLY IAW SRM.