What was found
FORWARD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT CORRODED FROM AFT FRAME OF DOOR CUTOUT BETWEEN BS 400 TO 500A, RBL 21. R & R THE SUPPORT IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT CORRODED FROM AFT FRAME OF DOOR CUTOUT BETWEEN BS 400 TO 500A, RBL 21. R & R THE SUPPORT IAW SRM AND DWG.