What was found
FORWARD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 500A TO 500D. R & R THE SUPPORT IAW SRM AND DRAWING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 500A TO 500D. R & R THE SUPPORT IAW SRM AND DRAWING.