What was found
AFT CARGO DOOR CUTOUT STRUCTURE FLOORBEAM STRAP CORRODED BETWEEN BS 808 TO BS 820, RBL 20. REPAIRED STRAP PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO DOOR CUTOUT STRUCTURE FLOORBEAM STRAP CORRODED BETWEEN BS 808 TO BS 820, RBL 20. REPAIRED STRAP PER SRM.