What was found
FLOORBEAM UPPER SURFACE CORRODED AT BS 986, BETWEEN RBL 30 TO RBL 45. REPAIRED FLOORBEAM IAW ER AND EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM UPPER SURFACE CORRODED AT BS 986, BETWEEN RBL 30 TO RBL 45. REPAIRED FLOORBEAM IAW ER AND EA.