What was found
AIR TURNBACK/DECLARED EMERGENCY, ON DEPARTURE ON THE CLIMB THROUGH 4,000 FT LOSS ALL HYDRAULIC A FLUID & PRESSURE, FOLLOWED BY SYSTEM A ENGINE & ELECTRIC HYDRAULIC PUMP LOW PRESSURE LIGHT. R&R NR 1 ENGINE DRIVEN HYDRAULIC PUMP PER AMM.