What was found
FORWARD CARGO LT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 400 TO BS 500A+9.3. R&R SUPPORT IAW SRM & DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO LT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 400 TO BS 500A+9.3. R&R SUPPORT IAW SRM & DWG.