What was found
FORWARD CARGO DOORWAY LOWER THRESHOLD SUB WEB CORRODED BETWEEN BS 440 TO BS 495, RBL 22. R&R WEB PER SRM & DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO DOORWAY LOWER THRESHOLD SUB WEB CORRODED BETWEEN BS 440 TO BS 495, RBL 22. R&R WEB PER SRM & DWG.