What was found
FORWARD CARGO R/H FLOOR TO SIDEWALL Z CORRODED BETWEEN BS. 500C TO BS. 500D, RBL 24. / R&R ANGLE IAW SRM AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO R/H FLOOR TO SIDEWALL Z CORRODED BETWEEN BS. 500C TO BS. 500D, RBL 24. / R&R ANGLE IAW SRM AND DWG.